Oil-immersed distribution transformers for outdoor and utility applications. Define rating, voltage ratio, losses and installation conditions together.

Illustration: Oil-immersed distribution transformers
Product illustration · configuration varies by project
Application & selection

A clear electrical and mechanical brief.

Outdoor distributionUtility substationsIndustrial power

Key information for configuration review

  • Rating (kVA) and quantity
  • Primary and secondary voltage, tapping range
  • Hermetic or conservator
  • Loss limits or loss capitalisation formula
Technical overview

Start with the
right specification.

Use this selection reference to prepare your project brief.

Reference values are not a model datasheet. Availability, standards and test coverage require confirmation for the offered equipment.

Download project sheets ↓
Selection reference +
Rated power, reference25, 50, 100, 160, 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500 kVA
Primary voltage11, 22, 33 kV
Secondary voltage400/230 V or 415/240 V
TappingOff-circuit tap changer, typically ±2 × 2.5%
Vector groupDyn11 (others to specification)
CoolingONAN
Insulating liquidMineral oil to IEC 60296; natural or synthetic ester subject to manufacturer confirmation
WindingsCopper or aluminium
AccessoriesOil level indicator, pressure relief device, thermometer; Buchholz relay for conservator type, to specification
Testing topics to confirm +

Confirm the applicable requirements, available reports and agreed test scope with the proposed manufacturer.

Routine tests (every unit, IEC 60076-1)Winding resistance; voltage ratio and phase displacement; short-circuit impedance and load loss; no-load loss and current; applied voltage and induced voltage tests; leak test
Type tests (per design)Temperature rise (IEC 60076-2); lightning impulse (IEC 60076-3); short-circuit withstand (IEC 60076-5) where the tender requires it
Project document package +
  • Model-specific datasheet and approved drawings
  • Applicable test reports and their coverage
  • Inspection, packing and delivery requirements
Manufacturing & quality →
Request a quotation

Send us your
requirement.

Ratings, quantities and destination are enough to start. Attach nothing here: we reply by email and ask for drawings or the tender schedule when needed.

Or email sales@trafovia.com. We reply within one working day (Beijing time).

We use your details only to answer this enquiry. See our privacy policy.

Project resources

Bring your next project
into focus.

Explore the equipment guide and prepare your requirements with our fillable project sheets.